Abstract

This paper proposes grid current shaping method using dc-link shunt compensator for three-phase diode rectifier system without electrolytic dc-link capacitor. In the proposed method, the diode rectifier system can satisfy the grid regulation IEC61000-3-12 without any power factor correction circuit or heavy grid filter inductor. The proposed grid current shaping method can be realized by applying DSC with reduced-rating components and without electrolytic capacitor, which is connected parallel to the dc link. Since DSC has no electrolytic capacitor, the system with DSC has high circuit reliability. Furthermore, DSC can enhance the system efficiency, especially in flux-weakening area, since the motor drive inverter recovers the reduced modulation index, which has been spent in the additional control for small passive components. This paper presents the control method for DSC and analyzes the effect of proposed method. The feasibility of proposed method is verified by simulation and experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.