Abstract

ABSTRACTA green iOS digital image colorimeter was fabricated for the determination of total iron in natural water. A mobile application operating on an iOS device was designed using Euclidean distance theory to perform iron determination. The application records the components of the color by storing red, green, and blue values as well as calculating the hue, saturation, brightness, and gray values using standard color theory. The component values obtained from the images of orange solutions of iron(II) complex with 1,10-phenanthroline were collected in a database and used for evaluation of the total iron concentration in water samples. Under the optimal conditions for solid-phase extraction used for sample preconcentration, the enrichment factor was 8.18. The iron concentration was determined by this device for concentrations from 0.01 to 1.0 ppm. The iOS digital image colorimeter achieved a limit of quantitation of 0.1 ppm. The accuracy and precision of the iOS digital image colorimeter were validated using a certified reference material, riverine water. The instrumentation was used for the analysis of natural water samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.