Abstract

An environmental friendly sorbent of polymeric ionic liquids modified graphene oxide-grafted silica (PILs@GO@Sil) was synthesized for solid-phase extraction (SPE) of phenolic acids. The sorbent was prepared via a chemical layer-to-layer fabrication including amidation reaction, surface radical chain-transfer polymerization and in situ anion exchange. After modification with PILs, the silica surface had higher positive potential so that it would exhibit stronger electrostatic interaction for acidic compounds compared with GO@Sil. The adsorption performance of phenolic acids was investigated through the theoretical calculation and static, kinetic state adsorption experiments. Under the optimized conditions, wide linear ranges were obtained with correlation coefficients ranging from 0.9912 to 0.9998, and limits of detection were in the range of 0.20-0.50μgL-1. Compared with other reported methods, the proposed PILs@GO@Sil-SPE-HPLC showed higher extraction efficiency. Finally, the black wolfberry yogurt and urine were analyzed as real samples and good recoveries spiked with standard solution were obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.