Abstract

Abstract. Grain combine and tractor fires in the U.S. cause over $10 million in annual property losses. Controlling machinery fires with fire detection and extinguishing hardware is one loss reduction approach. This study included the development and testing of a fully-automatic grain combine fire detection and dry chemical extinguishing system. The automatic system was tested on a variety of fire scenarios. The system performed well when crop residue and diesel fuel fires were detected soon after ignition. However, it was not fully effective after fires were allowed to burn for longer periods of time. Airflow through the engine compartment was found to be detrimental to extinguisher effectiveness. Resulting manual fire extinguisher selection and use recommendations included having at least one 4A:40BC (U.L. rating) or larger dry chemical fire extinguisher on every grain combine, mounting the extinguisher in a protected and accessible location, and shutting off the engine before attempting to extinguish any fire.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.