Abstract

Abstract We present the Generalized Polarization CALibration pipeline (GPCAL), an automated pipeline for instrumental polarization calibration of very long baseline interferometry (VLBI) data. The pipeline is designed to achieve a high calibration accuracy by means of fitting the instrumental polarization model, including the second-order terms, to data from multiple calibrator sources simultaneously. It also allows for using more accurate linear polarization models of calibrators for D-term estimation compared to the conventional way that assumes similar linear polarization and total intensity structures. This assumption has been widely used in the existing packages for instrumental polarization calibration but could be a source of significant uncertainties when there is no suitable calibrator satisfying the assumption. We demonstrate the capabilities of GPCAL by using simulated data, archival Very Long Baseline Array (VLBA) data of many active galactic nucleus (AGN) jets at 15 and 43 GHz, and our Korean VLBI Network (KVN) observations of many AGN jets at 86, 95, 130, and 142 GHz. The pipeline could reproduce the complex linear polarization structures of several sources shown in the previous studies using the same VLBA data. In addition, GPCAL reveals a complex linear polarization structure in the flat-spectrum radio quasar 3C 273 from the KVN data at all four frequencies. These results demonstrate that GPCAL can achieve a high calibration accuracy for various VLBI arrays.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call