Abstract

To determine the haptic position in transsclerally sutured posterior chamber lenses. Fifty eyes with transsclerally sutured posterior chamber lenses were evaluated gonioscopically to determine the superior haptic position using previous peripheral iridectomies. The superior haptic of the transsclerally sutured posterior chamber lens was visualized in 31 (62%) of the eyes. In 24 (77%) of the 31 eyes, the haptic was within the ciliary sulcus, and in seven (23%), it was located posterior to the sulcus. A fibrotic membrane was detected around the sutured haptic in 20 (83%) of the 24 lenses located within the sulcus, whereas no fibrosis was seen surrounding the seven haptics outside the sulcus (P < .0001). Proper positioning of the haptics may be correlated with the development of fibrosis surrounding the haptic and therefore may be an important factor in the long-term stability of transsclerally sutured posterior chamber lenses.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.