Abstract
Wearable biosensors have received significant attention due to the possibility of measuring physiological signals on demand. Particularly, the monitoring of electromyographic (EMG) signals on demand by wearable platforms has significant potential to revolutionize the diagnostics and treatment of neuromuscular diseases and for advancing human–computer interfaces. Electronic textile-based biosensors have several advantages, including the simple scale-up process and the ease of fabricating multiple large area electrodes over the whole body to obtain precise measurements. Hence, the electronic textile production requires an affordable approach to fabricate biocompatible and biostable electronic circuits on textile materials. This work explores the possibility of combining screen printing and electrodeposition techniques to produce a biostable nanocomposite-based EMG biosensor on textile. Screen printing was selected to fabricate conductive fabrics that would ultimately be a highly durable textile-based sensor. Silver paste, including microscale silver flakes, was printed on PET/cotton blended fabrics. However, the microscale silver surface was limited for EMG sensors due to low surface area and toxicity, causing low signal detection performance and skin irritation. Gold nanoparticles (Au NPs) were deposited on silver flakes to address the requirements of high-performance and biocompatible biosensors. We confirmed that the gold functionalization improved electrical and electrochemical performance. In addition, various tests were performed to determine electrochemical and biological stability under physiological conditions. The test results proved that Au NPs have successfully encapsulated the surface of silver flakes, preventing the exposure of the silver to the physiological environment. EMG signal recording was performed to confirm the functionalization effect that improved the signal to noise ratio (SNR) of 12.5 with 120 nm Au NPs. Moreover, EMG sensing from bicep workouts and finger movements showed the high sensitivity of the electronic fabrics. Although the SNR of EMG signals dropped to 7.2 after a 15-time washing test, the stabilized SNR after 5 washing cycles indicated that the Au/Ag biosensors showed washing durability. The study demonstrates that this affordable approach can be considered for large-scale production of wearable EMG biosensors.
Highlights
Non-invasive wearable biosensors represent an important class of bioelectronic tools for detection of physiological signals in various environments without discomfort and tissue damages.1–4 Electronic textile is a versatile platform to fabricate wearable biosensors due to its lightweight, softness, and accessibility for on demand measurements over extended time.5,6 The devices from electrically conductive 2D textile can interface with a large area of human skin to measure electrocardiogram (ECG) or electromyography (EMG) from the heart or muscles, respectively
polyethylene terephthalate (PET) has been generally used for daily textiles due to durability, lightweight, and wrinkle resistance, PET showed poor printing performance caused by dye migration
We fabricated textile-based EMG sensors equipped with affordable material base and proposed an easy-to-fabricate method of screen printing, leading to large-scale monitoring
Summary
Non-invasive wearable biosensors represent an important class of bioelectronic tools for detection of physiological signals in various environments without discomfort and tissue damages.1–4 Electronic textile is a versatile platform to fabricate wearable biosensors due to its lightweight, softness, and accessibility for on demand measurements over extended time.5,6 The devices from electrically conductive 2D textile can interface with a large area of human skin to measure electrocardiogram (ECG) or electromyography (EMG) from the heart or muscles, respectively. PET has been generally used for daily textiles due to durability, lightweight, and wrinkle resistance, PET showed poor printing performance caused by dye migration.41,42 In addition, hydrophobicity due to low surface energy, lack of polarity to adhere polar organic solvent-based silver paste, and smooth surface restricts the coating property, resulting in poor adhesion between PET fabrics and Ag flakes in paste.43,44 We confirmed that the screen-printed Ag layer had low durability after the washing and friction test, generating delamination from the PET surface (Fig. S1).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.