Abstract

Background/Aims: Recent evidences suggest that hemodialysis (HD) induces glycemic variations in diabetic patients. Continuous glucose monitoring (CGM) devices measure interstitial glucose in a ‘Holter-like' manner thereby improving the glycemic control assessment method. Methods: A CGM device (Medtronic iPRO) was used on 12 diabetic patients with chronic HD for 6 days to assess intra- and extra-dialytic interstitial glucose. Results: In all enrolled patients, HD was associated with a decrease of interstitial glucose values. Intradialytic glucose nadir was 79 mg/dl and it was reached at the third hour after the beginning of the session. At the end of HD, interstitial glucose increased in all patients and a glycemic peak (187 mg/dl) occurred after an average time of 2.5 h. No episodes of nocturnal hypoglycemia occurred. Conclusion: HD is associated with significant intradialytic reduction of glycemia and postdialytic hyperglycemia. CGM devices result in better monitoring of glycemic trends in diabetic patients on chronic HD and could improve insulin management.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call