Abstract

Glued-in rods have potential for use as moment-resisting connections in timber structures. There has been minimal research to date conducted on the performance of glued-in rods acting under both axial force and moment. The influence of increasing embedded length of the glued-in rod on the strength of the system was assessed using a pull-bending test which subjected the connection to this force combination. The longest length (600 mm) had a pull-out capacity 213% greater than the shortest (80 mm). To reduce instances of splitting in the timber end distance was varied. Optimum end distance of 42 mm (3.5dr) was identified with further increase having minimal impact upon overall strength.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.