Abstract

A feasible method to fabricate glucose biosensor was developed by covalent attachment of glucose oxidase (GOx) to a silica nanoparticle monolayer modified gold electrode. Electrochemical impedance spectroscopy (EIS) of ferrocyanide followed the assembly process and verified the successful immobilization of GOx on silica nanoparticle modified on gold electrodes. Cyclic voltammetry (CV), performed in the presence of excess glucose and artificial redox mediator (ferrocenemethanol), allowed to quantify the surface concentration of electrically wired enzyme. The signal of proposed electrode was more than 2.5 times of that on electrode lacking silica nanoparticles. As a result, silica nanoparticles are a good biocompatible solid support for enzyme immobilization.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.