Abstract

The Global Trigger (GT) is the final step of the CMS Level-1 Trigger and implements the ``menu'' of triggers, which is a set of selection requirements applied to the final list of objects (such as muons, electrons or jets) to trigger the readout of the detector and serve as basis for further calculations by the High Level Trigger. Operational experience in developing trigger menus from the first LHC run has shown that the requirements increased as the luminosity and pile-up increased. The new GT (μGT) is designed based on Xilinx Virtex-7 FPGAs, which combine unsurpassed flexibility with regard to scalability and high robustness. Furthermore, a custom board which receives signals from legacy electronics and basic binary inputs from less complex trigger sources is presented. Additionally, this paper describes the architecture of a distributed testing framework and the Trigger Menu Editor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.