Abstract

We have analyzed the gas filter radiometer approach for long-term monitoring of stratospheric HCl, HF, CH(4), and H2O using solar occultation at selected intervals in the 2-6 microm range. Our analysis shows that this instrument technique is feasible. This conclusion is based on a simulation study in which we evaluated the effect of various experiment errors on retrieval accuracy. The instrument errors used were based on measurements made on a breadboard model gas filter radiometer. The results show that HCl and HF can be measured with an rms error of 10% and CH(4), and H2O with an error of 15% over the 10-30-km range.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.