Abstract
* The optimal amount of glenohumeral radial mismatch in anatomic shoulder arthroplasty remains undefined, but the consensus among multiple studies suggests between 4 and 8 mm.* Current implant designs offer mismatch of the radii of curvature between the humeral head and the glenoid ranging from 1 to 38 mm.* Clinically, conforming glenoids demonstrate greater loosening and lucency scores compared with nonconforming glenoid components; however, survivorship advantages have not been proven.* There remains a range of radial mismatch tolerances that improve glenohumeral kinematics and wear patterns, which appear to be greater when the glenoid is loaded centrally and is supported in neutral glenoid version.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.