Abstract

The polymer glass transition is an important property in a wide variety of applications. The glass transition temperature of a polymer composite or confined thin film can be significantly different to the pure polymer. Molecular dynamics simulations are useful for providing molecular level insight and prediction, particularly at interfaces, that are not easily observable experimentally. However, there are significant methodological uncertainties in calculating the polymer glass transition temperature using molecular dynamics simulations. In this work we investigate how the cooling method, fitting range and statistical variation affects the calculated glass transition temperature of polyethylene. We found that it is necessary to perform multiple independent simulations to obtain statistically significant results, and that appropriate fitting ranges must be chosen. The methodological findings were used to investigate the difference in glass transition temperature between pure polyethylene and a polyethylene film confined between graphene surfaces. It was found that the glass transition temperature of a 9 nm thick confined film was higher than bulk polyethylene by approximately 15 K.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.