Abstract

The forces required to debond orthodontic brackets on human teeth were studied in vitro. The brackets were bonded with different glass ionomer cements (GICs), and a composite resin (Concise). The shear force required to remove the brackets was recorded at different time intervals after bonding. The bond strength was considerably lower for the GICs compared with brackets bonded with the composite resin, at all time intervals that were studied. Moreover, the bond strength increased more slowly for the GICs compared with the resin. Different GICs displayed a varying setting time. The bonding strength of GICs increased more than 50 per cent between 10 and 20 minutes setting time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.