Abstract
Stochastic processes are widely used to describe continuous degradation, among which the monotonically increasing degradation is most common. However, the observation is often perturbed with undesired noise due to sensor or measurement errors in practice. This paper focuses on predicting the degradation growth and estimating the system’s remaining useful life based on noisy observations. The deterioration is modeled by a Transformed Gamma process, accounting for both time- and state-dependent degradation increments. Measurement error is assumed to follow a normal distribution. We propose to use an improved Gibbs sampler to estimate the hidden degradation states. Combined with Expectation–Maximization, the Gibbs sampler can be used for model parameter estimation. The probability of false/failed alarm and distribution of remaining useful life are also derived. The proposed method is applied to choke valve erosion data collected from NTNU’s laboratory, and the influence of covariates on the degradation rate is discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.