Abstract
The latent tracks formed on CR-39 solid state track detector on exposure of alpha radiations emanating from a collimated 241Am source were developed by a chemical etching method. Alpha track images were captured by an optical microscope and were processed by using Image Pro-Plus (6.0) software. GEANT4 simulations were carried out to obtain the angular and energy distribution profiles of the alpha particles. Apart from fluence, geometric parameters like aspect ratio (the ratio of the major to minor axis) and the depth profiles of etched tracks were measured experimentally and correlated with simulated angular and energy profile of incident radiations. Reasonable agreement was observed in the fluence and depth profile information obtained from experiments and simulations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.