Abstract

This article analyzes the potential of air-core transformers (ACTs) for realizing medium-voltage high-power isolated dc–dc converters. ACTs, i.e., transformers without magnetic cores, are particularly interesting for their simple construction and reduced weight. However, the reduced magnetizing inductance, the reduced magnetic coupling, and the stray fields are challenging aspects for the design of ACTs. A comprehensive model of the ACT (e.g., magnetic field patterns, skin and proximity losses, shield’s eddy currents, harmonics, insulation constraints, and thermal limit) is proposed and verified with measurements obtained with a prototype. Afterward, a complete multiobjective optimization of a series resonant converter (SRC) operating as a dc transformer (DCX) between two 7 kV buses with a rated power of 166 kW is conducted. Two different geometries are considered for the ACT: concentric cylindrical coils and planar spiral coils. As a result, the optimal ACT (operated at 162 kHz) features extreme power densities of 7.5 kW/dm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> and 31 kW/kg, which confirms the superiority of ACTs regarding the gravimetric power density. The calculated efficiencies are 99.5% and 98.7% for the ACT and the complete dc–dc converter, respectively. Finally, the different tradeoffs are highlighted and analyzed, e.g., mass, volume, efficiency, switching frequency, part-load behavior, and insulation distance.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call