Abstract

An evaluation of geometrical nonlinear effects on three pylons composite girder cable-stayed bridge is presented. According to the structure and mechanical characteristics, a space twin-girder finite element model of whole bridge is established through general large-scale finite element analysis software ANSYS, sag effect, and large displacement and beam-column effects are considered, the nonlinear static response of three pylons composite girder cable-stayed bridge is calculated under dead load. the results show that sag effects on cables force is most obvious, large displacement and beam-column effects on main girders deflection and internal force is larger, all nonlinear effects are mutually coupled and should be taken into account for structure design of three pylons composite girder cable-stayed bridge.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.