Abstract

Previous analyses [Z. Yan and J. Chen, J. Appl. Phys. 72, 1 (1992); J. Chen and Z. Yan, ibid., 84, 1791 (1998); Lin et al., Physica B 344, 147 (2004); Yang et al., ibid., 364, 33 (2005); Xia et al., ibid., 381, 246 (2006).] of irreversibilities in magnetic refrigerators overlooked several important losses that could be dominant in a real active magnetic regenerative refrigerator (AMRR). No quantitative expressions have been provided yet to estimate the corresponding entropy generations in real AMRRs. The important geometric parameters of AMRRs, such as the aspect ratio of the active magnetic regenerator and the refrigerant diameter, are still arbitrarily chosen. Expressions for calculating different types of entropy generations in the AMRR were derived and used to optimize the aspect ratio and the refrigerant diameter. An optimal coefficient of performance (15.54) was achieved at an aspect ratio of 6.39 and a refrigerant diameter of 1.1mm for our current system. Further study showed that the dissipative sources (e.g., the fluid friction and the unbalanced magnetic forces) in AMRRs, which were overlooked by previous investigations, could significantly contribute to entropy generations.