Abstract
ObjectivesThe goal of this study was to evaluate the incidence and effects of underdosage of injured segments during intracoronary irradiation and to define the minimal length of safety margin required to avoid mismatched source placement. BackgroundUnderdosage of injured segments due to misplacement of active source has been suggested as the underlying mechanism for the occurrence of edge restenosis. MethodsBaseline angiograms of 112 vessels in 109 patients with in-stent restenosis undergoing coronary reintervention followed by intracoronary irradiation (192Ir: Checkmate, Cordis, Miami, Florida; 32P: Gallileo, Guidant, Houston, Texas; 90Sr/Y: Beta-Cath, Novoste, Norcross, Georgia) were analyzed. The distances between the outermost injury and outermost end of “reference isodose length” (RIL), defined as a segment with ≥90% of reference dose at 1 mm vessel wall depth, were measured. “Safety margin” was defined as the distance between the outermost injury and outermost end of the RIL, “geographical miss” (GM) as a complete injured segment not being covered by the RIL, and “restenosis” as the percent diameter stenosis >50%. ResultsBaseline angiographic analysis was performed for 224 edges in 112 vessels. Geographical miss was found in 46 (20.6%) edges. The incidence of target lesion restenosis within the 78 vessels with available follow-up was 43.3% for patients with GM versus 14.9% for patients with no GM (p = 0.005). Analysis of various injured segments exposed highest restenosis rates in injured segments with negligible irradiation (27.8%) in comparison with injured segments with dose fall-off (16.7%) or injured segments with full-dose irradiation (7.7%) (p = 0.006). Receiver operating curve analysis revealed a safety margin of 10 mm required per vessel (i.e., 5-mm safety margin/edge) to achieve 95% specificity of GM. ConclusionsGeographical miss is associated with a higher incidence of restenosis at the corresponding edges. Restenosis was more pronounced in injured segments with negligible irradiation than in injured segments at the dose fall-off zones. We recommend a safety margin of 10 mm per vessel to minimize GM.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.