Abstract

IntroductionThe diagnosis of tuberculous lymphadenitis (TBL) remains challenging. The routinely used methods (cytology and smear microscopy) have sub-optimal sensitivity. Recently, WHO recommends GeneXpert to be used as the initial diagnostic test in patients suspected of having extra-pulmonary tuberculosis (EPTB). However, this was a conditional recommendation due to very low-quality evidence available and more studies are needed. In this study we evaluated the performance of Xpert for the diagnosis of TBL on concentrated fine needle aspirates (FNA) in Southwest Ethiopia.MethodsFNA was collected from presumptive TBL cases. Two smears were prepared from each aspirate and processed for cytology and conventional microscopy. The remaining aspirate was treated with N-acetyl-L-cysteine-NaOH and centrifuged for 15minutes at 3000g. The concentrated sediment was used for culture and Xpert test. Capilia TB-Neo test was used to differentiate M. tuberculosis complex (MTBC) from non-tuberculous mycobacteria (NTM). Composite bacteriological methods (culture and/or smear microscopy) were considered as a reference standard.ResultOut of 143 enrolled suspects, 64.3% (92/143) were confirmed TBL cases by the composite reference standard (CRS). Xpert detected M. tuberculosis complex (MTBC) in 60.1% (86/143) of the presumptive TBL cases. The sensitivity of Xpert compared to CRS was 87.8% [95% CI: 81.0–94.5] and specificity 91.1% [95% CI: 82.8–99.4]. The sensitivity was 27.8% for smear microscopy and 80% for cytology compared to CRS. Cytology showed the lowest specificity (57.8%). Xpert was positive in 4 out of 45 culture- and smear-negative cases. Among 47 cytomorphologically non-TBL cases, 15 were positive on Xpert. More than half of Xpert-positive cases were in the range of very low cut-off threshold values (28<Ct<38). Resistance to rifampicin was identified in 4.7% (4/86) of Xpert-positive cases.ConclusionXpert test showed a high sensitivity and specificity for the diagnosis of TBL on concentrated FNA samples. In addition, Xpert offered rapid detection of rifampicin-resistant M. tuberculosis strains from lymph node aspirates.

Highlights

  • The diagnosis of tuberculous lymphadenitis (TBL) remains challenging

  • Xpert offered rapid detection of rifampicin-resistant M. tuberculosis strains from lymph node aspirates

  • Ethiopia ranks eighth in the list of the 22 high TB burden countries and 3rd in terms of the number of extra-pulmonary tuberculosis (EPTB); of which 80% is localized in lymph nodes [1,2]

Read more

Summary

Introduction

The diagnosis of tuberculous lymphadenitis (TBL) remains challenging. The routinely used methods (cytology and smear microscopy) have sub-optimal sensitivity. WHO recommends GeneXpert to be used as the initial diagnostic test in patients suspected of having extra-pulmonary tuberculosis (EPTB). This was a conditional recommendation due to very low-quality evidence available and more studies are needed. In this study we evaluated the performance of Xpert for the diagnosis of TBL on concentrated fine needle aspirates (FNA) in Southwest Ethiopia

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.