Abstract

We have extended the method of Alvarez [J. Am. Optom. Assoc. 49, 24 (1978)] to generate a variable magnitude of third-order spherical and/or coma aberration by using a combination of fourth-order plates with a magnification system. The technique, based on the crossed-cylinder aberroscope, is used to measure the wave-front aberration generated by the plates. The method has been applied to correct the third-order spherical aberration generated by an artificial eye as well as the coma produced by a progressive addition ophthalmic lens. The simplicity of the method and its relatively low cost make it attractive for partial correction of the aberrations of the eye.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call