Abstract

We have studied the motion of a plasma piston (PP) in the channel of an electromagnetic railgun accelerator with a cross-sectional area of 36 and 86 mm2. The accelerator was placed in a chamber that could be evacuated and then filled with helium or argon at a pressure within 25–250 Torr. It is established that the stationary PP velocity in the channel depends on the gas type and pressure. The results are satisfactorily described by the proposed model. Experimental data can be used for evaluating the effective running inductance of the accelerator and the coefficient of erosion of the electrode material.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.