AbstractThis study uses fragility curves to focus on the seismic safety evaluation of RC hospital buildings in Turkey. Three hospital buildings with varying heights of 3–5 stories are selected, and a set of fragility curves are generated for each class. The major parameters considered in this study are the number of stories, lateral stiffness, strength, and displacement capacities of the selected template designs. A large number of pushover and time history analyses are deployed under a set of 100 strong ground motion records. Fragility curves are generated based on the analysis results for each of the typical buildings. Peak ground velocity (PGV) is selected as the measure of seismic intensity. From the generated sets of the fragility curves, it is observed that damage probabilities are significantly affected by the concrete and detailing quality. Using the constructed fragility curves, collapse probabilities of existing public buildings were estimated according to PGV values. The estimated damage by fra...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.