Abstract
Voltage stability in medium-voltage DC (MVDC) power systems on ships is a key design goal. MVDC bus voltage stability can be impaired because of the presence of power electronic converters that can induce negative incremental resistance instabilities. This study presents a control strategy that stabilises MVDC bus voltage in the presence of destabilising constant power load converters. A state-feedback adaptive control is designed by linearisation and implemented using controlled interface converters connecting the MVAC alternators to the MVDC bus. Large signal stability of the control system is assessed using Lyapunov techniques. The proposed control is verified against both average-simplified and detailed time-domain numerical simulations, thus providing a two-way comparison.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.