Abstract
Concentration gradients have important applications in chemical and biological studies. Here we have achieved rapid generation of spatially and temporally controllable concentration gradients of diffusible molecules (i.e. proteins or toxins) in a portable microfluidic device. The formation of the concentration gradients was initiated by a passive-pump-induced forward flow and further optimized during an evaporation-induced backward flow. We were able to stabilize the gradient for up to 12 hours by stopping the flow. The computational simulations illustrated the combined effects of convection and diffusion on the gradient generation, and fit well with the experimental data. HL-1 cardiac cells were cultured in the device, and were shown to be responsive to the stabilized concentration gradient of a cardiac toxin, alpha-cypermethrin. The approach presented here may be useful for many biological and chemical processes that require rapid generation of long-range gradients in a portable microfluidic device.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.