Abstract

A simple and wideband calibration method for calibrating electric field sensors and probes with traceability to national standards using a GTEM cell and a transfer standard is investigated. We also introduce a method for the isotropic response measurement for electric field probes. A correction way for calibrating combined electric field strength in GTEM cell. A comparison with TEM cells is made to validate the proposed method.