Abstract

Fast Fourier transform-based phase screen simulations give accurate results only when the screen size (G) is much larger than the outer scale parameter (L0). Otherwise, they fall short in correctly predicting both the low and high frequency behaviors of turbulence-induced phase distortions. Subharmonic compensation is a commonly used technique that aids in low-frequency correction but does not solve the problem for all values of screen size to outer scale parameter ratios (G / L0). A subharmonics-based approach will lead to unequal sampling or weights calculation for subharmonics addition at the low-frequency range and patch normalization factor. We have modified the subharmonics-based approach by introducing a Gaussian phase autocorrelation matrix that compensates for these shortfalls. We show that the maximum relative error in structure function with respect to theoretical value is as small as 0.5% to 3% for (G / L0) ratio of 1/1000 even for screen sizes up to 100 m diameter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.