Abstract

This paper obtains generalised availability measures, e.g. interval reliability, joint interval reliability, joint availability and expected number of system failures etc. for a multi-component system with deterioration in storage. We discuss here two such models under different assumptions. Regenerative point technique of Markov Renewal Process has been employed to obtain the aforesaid measures. This paper further unifies the treatment as employed to simple and two-unit standby redundant systems earlier [4,5,6].

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.