Abstract
This study proposes a new method for calculating gamma-ray buildup factors in multilayer shields. The formula combines the buildup of single-layer shields with products and quotients. The tests have shown that the approximating formula reproduces the reference data of double layer shields very well for most cases. With the same parameters and with a new physical consideration that takes into account in a global way the degradation of the gamma-ray energy spectrum, the buildup factors of three and five layer shields were also very well reproduced. The new formula is incorporated in the new version of the MERCURE-6 point-kernel code.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.