Abstract

A graphical method is employed to give a generalized bird's-eye view of the existing data for critical heat flux (CHF) in internally and uniformly heated vertical annuli with zero inlet subcooling. 301 data points collected from 25 sources are used for this purpose, including 7 different fluids (water, R-12, R-114, acetone, toluene, monoisopropyl-biphenyl, and sodium), axial length of heated rod from 0.0762 to 8.84 m, outer diameter of heated rod from 0.00500 to 0.0964 m, inner diameter of unheated shroud tube from 0.0127 to 0.101 m, and vapor/liquid density ratio from 0.0000580 to 0.160.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.