Abstract

The aims of this study were to evaluate the morphologic characteristics and growth pattern of hepatic tumors in H-ras 12V transgenic (TG) mice using a micro-magnetic resonance (MR) system and to assess the usefulness of gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid (Gd-EOB-DTPA) enhancement for the detection of hepatic tumors in these mice. Hepatocellular carcinoma lines were established to allow insertion of the H-ras 12V transgene under the control of the albumin enhancer/promoter. Seven H-ras 12V TG mice and four wild-type mice were included in this study. The mice underwent various MR imaging examinations, including T1-weighted imaging (repetition time, 300 ms; echo time, 11 ms), Gd-EOB-DTPA-enhanced T1-weighted imaging (dose, 0.025 mmol/kg), and T2-weighted imaging (repetition time, 3500 ms; echo time, 36 ms), with a 4.7-T MR scanner, at 4, 6, 8, and 9 months of age. All mice were euthanized after the final MR imaging procedure, except for one TG mouse and two wild-type mice that were euthanized after MR imaging procedures at 4 months of age. For imaging analysis, the tumor characteristics in each MR sequence, including tumor size, number, and signal intensity (SI), were recorded, and the contrast-to-noise ratio and contrast enhancement ratio were calculated to quantify the SI of the tumor. The MR images were correlated with the findings of histopathologic examinations. No tumors were detected in the four wild-type mice. In the six TG mice, a total of 67 tumors were found in histopathologic specimens obtained at 9 months of age. Of the 67 tumors, 62 were detected on Gd-EOB-DTPA-enhanced T1-weighted images with fat saturation. The majority of hepatic tumors showed high SI on T1-weighted images without fat saturation. The SI diminished on T1-weighted images with fat saturation. The tumor contrast-to-noise ratio for Gd-EOB-DTPA-enhanced T1-weighted imaging was significantly better than that for the other sequences. The tumors were histopathologically confirmed as hepatocellular adenomas (n = 32) and well-differentiated hepatocellular carcinomas (n = 35). Micro-MR imaging can reveal the characteristics of hepatic tumors in a live murine model. Gd-EOB-DTPA-enhanced T1-weighted imaging is helpful in the detection of hepatic tumors in H-ras 12V TG mice.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.