Abstract

BackgroundDespite the increasing use of RNAseq for transcriptome analysis, microarrays remain a widely-used methodology for genomic studies. The latest generation of Affymetrix/Thermo-Fisher microarrays, the ClariomD/XTA and ClariomS array, provide a sensitive and facile method for complex transcriptome expression analysis. However, existing methods of analysis for these high-density arrays do not leverage the statistical power contained in having multiple oligonucleotides representing each gene/exon, but rather summarize probes into a single expression value. We previously developed a methodology, the Sscore algorithm, for probe-level identification of differentially expressed genes (DEGs) between treatment and control samples with oligonucleotide microarrays. The Sscore algorithm was validated for sensitive detection of DEGs by comparison with existing methods. However, the prior version of the Sscore algorithm and a R-based implementation software, sscore, do not function with the latest generations of Affymetrix/Fisher microarrays due to changes in microarray design that eliminated probes previously used for estimation of non-specific binding.ResultsHere we describe the GCSscore algorithm, which utilizes the GC-content of a given oligonucleotide probe to estimate non-specific binding using antigenomic background probes found on new generations of arrays. We implemented this algorithm in an improved GCSscore R package for analysis of modern oligonucleotide microarrays. GCSscore has multiple methods for grouping individual probes on the ClariomD/XTA chips, providing the user with differential expression analysis at the gene-level and the exon-level. By utilizing the direct probe-level intensities, the GCSscore algorithm was able to detect DEGs under stringent statistical criteria for all Clariom-based arrays. We demonstrate that for older 3′-IVT arrays, GCSscore produced very similar differential gene expression analysis results compared to the original Sscore method. However, GCSscore functioned well for both the ClariomS and ClariomD/XTA newer microarrays and outperformed existing analysis approaches insofar as the number of DEGs and cognate biological functions identified. This was particularly striking for analysis of the highly complex ClariomD/XTA based arrays.ConclusionsThe GCSscore package represents a powerful new application for analysis of the newest generation of oligonucleotide microarrays such as the ClariomS and ClariomD/XTA arrays produced by Affymetrix/Fisher.

Highlights

  • Despite the increasing use of RNAseq for transcriptome analysis, microarrays remain a widely-used methodology for genomic studies

  • The GCSscore package represents a powerful new application for analysis of the newest generation of oligonucleotide microarrays such as the ClariomS and ClariomD/XTA arrays produced by Affymetrix/Fisher

  • To confirm that the new algorithm performed as expected, we analyzed these 430 2.0 arrays first using the perfect match (PM)-MM method found in the GCSscore package with the original sscore package

Read more

Summary

Introduction

Despite the increasing use of RNAseq for transcriptome analysis, microarrays remain a widely-used methodology for genomic studies. Since expression “differences” rather than absolute expression levels are generally the goal in microarray studies, our laboratory previously developed the Sscore algorithm for analysis of Affymetrix oligonucleotide microarrays for detecting significant expression changes between paired samples [2]. This entailed comparing individual oligonucleotide probes within each probeset between two samples, after applying a heteroscedastic error correction model. Prior work demonstrated the advantage of the Sscore method over probe summarization techniques such as RMA for Affymetrix microarray analysis, for experiments having smaller numbers of replicates [2, 3] This advantage prompted development of a Bioconductor R package, sscore, for application of the original Sscore method on Affymetrix microarrays [4]. This algorithm has been utilized in publications across multiple laboratories for studies based on 3′ IVT array technology [5,6,7,8,9,10,11,12]

Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.