Abstract

Empirical mode decomposition (EMD) is a powerful algorithm that decomposes signals as a set of intrinsic mode function (IMF) based on the signal complexity. In this study, partial reconstruction of IMF acting as a filter was used for noise reduction in ECG. An improved algorithm, ensemble EMD (EEMD), was used for the first time to improve the noise-filtering performance, based on the mode-mixing reduction between near IMF scales. Both standard ECG templates derived from simulator and Arrhythmia ECG database were used as ECG signal, while Gaussian white noise was used as noise source. Mean square error (MSE) between the reconstructed ECG and original ECG was used as the filter performance indicator. FIR Wiener filter was also used to compare the filtering performance with EEMD. Experimental result showed that EEMD had better noise-filtering performance than EMD and FIR Wiener filter. The average MSE ratios of EEMD to EMD and FIR Wiener filter were 0.71 and 0.61, respectively. Thus, this study investigated an ECG noise-filtering procedure based on EEMD. Also, the optimal added noise power and trial number for EEMD was also examined.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.