Abstract

The reliability of the gate oxide on large-area surface defects (trapezoid-shaped and obtuse triangular defects) in 4H-SiC epitaxial wafers is discussed. Time-dependent dielectric breakdown measurements revealed that a reduction in charge-to-breakdown (Qbd) occurred at a MOS capacitor including the downstream line of those defects. The deterioration of Qbd was at the same level in trapezoid-shaped defects and obtuse triangular defects. A cross-sectional transmission electron microscope (TEM) image and the simulation of the electric field distribution for the MOS structure indicated that the local fluctuation of the oxide thickness and/or the roughness of the interface on the downstream lines caused the degradation of the reliability of the MOS capacitors.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.