Abstract

BackgroundGastrointestinal bleeding (GIB) affects up to 40% of continuous-flow left ventricular assist device (CF-LVAD) recipients. A higher risk of GIB is seen in CF-LVAD recipients with lower device pulsatility without a known mechanism. One hypothesis is that the novel hemodynamics in CF-LVAD recipients affect angiogenesis signaling. We aimed to (1) measure serum levels of angiopoietin (Ang)-1, Ang-2, and VEGF-A in CF-LVAD recipients with and without GIB and in healthy controls and (2) evaluate correlations of those levels with hemodynamics. MethodsWe recruited 12 patients with CF-LVADs (six who developed GIB after device implantation) along with 12 age-matched controls without heart failure or GIB and measured Ang-1, Ang-2, and VEGF-A levels in serum samples from each patient. ResultsCF-LVAD recipients had significantly higher Ang-2 and lower Ang-1 levels compared to controls with no difference in VEGF-A levels. CF-LVAD recipients with GIB had lower Ang-1 levels than those without GIB. There were trends for pulse pressure to be positively correlated with Ang-1 levels and negatively correlated with Ang-2 levels in CF-LVAD recipients with no correlation observed in healthy controls. ConclusionCF-LVAD recipients demonstrated a shift toward a pro-angiogenic phenotype in the angiopoietin axis that is significantly associated with GIB and may be linked to low pulse pressure.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call