Abstract
Introduction: Endoscopic argon plasma coagulation (APC) is gaining widespread usage but its risk is underreported. Clinical Picture: A 74-year-old man who received radical radiotherapy for gastric carcinoma 6 months ago was admitted for anaemia and maelena. Gastroscopy revealed haemorrhagic radiation gastritis. Endoscopic APC was performed but terminated when he complained of severe epigastric pain. Computed tomography scan showed gastric pneumatosis. Treatment: His pain subsided with a period of overnight rest and observation. Outcome: He continued to have 3 sessions of endoscopic APC at monthly intervals and at 10 months posttreatment, his haemoglobin remained stable at 11.1 g/dL. Conclusions: This case report highlights a complication of gastric pneumatosis and discusses the safe usage of this modality of endoscopic haemostasis. This is to increase cognisance of this potentially fatal complication among endoscopists.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.