Abstract
A method was developed for the determination of the lindane content of commercial household insecticide spray aerosols. After the propellant is removed from the chilled contents of the spray packages the hydrocarbon solution is analysed for its lindane content by electron-capture gas chromatography. Pure α-isomer of hexachlorocyclohexane serves as the internal standard. Experimental error is ± 5%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.