Abstract

This paper examines the gas flow performance of needle-punched geosynthetic clay liners (GCLs) overlap seams over a range of gravimetric moisture content, including the effect of vertical stress and unevenness of the overlaps. The gas permeability of the GCL overlapped seams was higher than that of intact GCLs, especially at higher gravimetric moisture content, as the intactness of the overlapped areas was challenging to maintain due to the GCL swelling process. The gas flow rate of uneven overlapped GCLs was greater than that of a flat overlap (even seam) irrespective of the vertical stress. This paper highlights the importance of factoring in the possibility of the unevenness of the GCL panels overlaps when assessing gas migration through cover systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.