Abstract
We measured the gas-particle partitioning of vehicle emitted primary organic aerosol (POA) in a traffic tunnel with three independent methods: artifact corrected bare-quartz filters, thermodenuder (TD) measurements, and thermal-desorption gas-chromatography mass-spectrometry (TD-GC-MS). Results from all methods consistently show that vehicle emitted POA measured in the traffic tunnel is semivolatile under a wide range of fleet compositions and ambient conditions. We compared the gas-particle partitioning of POA measured in both tunnel and dynamometer studies and found that volatility distributions measured in the traffic tunnel are similar to volatility distributions measured in the dynamometer studies, and predict similar gas-particle partitioning in the TD. These results suggest that the POA volatility distribution measured in the dynamometer studies can be applied to describe gas-particle partitioning of ambient POA emissions. The POA volatility distribution measured in the tunnel does not have significant diurnal or seasonal variations, which indicate that a single volatility distribution is adequate to describe the gas-particle partitioning of vehicle emitted POA in the urban environment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.