Abstract

Water, methanol, toluene and ligroin were aerated in bubble column of 0.15 m I.D. and a height of 4.3 m . Using a gas disengagement technique, the holdups of large were found to be similar in all liquids whereas the holdups of small bubbles differed significally. Oxygen mass transfer studies with a dynamic absorption method were impaired by height-and time-dependent oxygen depletion in the gas phase. Only at low dispersion heights, there was agreement with the results of a steady state method. Photographic determination of the small bubbles' diameters and knowledge of their holdup fraction allowed to estimate their potential contributions to the mass transfer rate at gas flow rates up to 0.2m/s. These contribution were generally high and in ligroin the estimates even exceeded the observed total oxygen transfer rate. It is conclude that the finite rates of coalescence and break-up reduce the driving force for mass transfer from the small bubble fraction.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.