Abstract

A gas chromatographic method for the determination of 1,3-dihydro-3-phenylspiro[isobenzo-1,4-piperidine], HP 505, in plasma, red blood cells and urine has been developed. HP 505 and internal standard are extracted from basified fluid with hexane and then back extracted into acetic acid. After re-extraction into hexane, HP 505 and internal standard are analysed by gas-liquid chromatography as the N-propionyl derivatives using a nitrogen-specific detector. Concentrations of HP 505 can be measured over the range 2–100 ng/ml plasma. The method has been applied to the analysis of biological fluids from volunteers receiving oral doses of HP 505.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.