Abstract

The gas holdup and liquid phase axial dispersion coefficient are measured in two semi batch packed bubble columns, 10 and 15 cm diameter for an air–water system, at atmospheric conditions. The experiments were carried out using a transient method (the tracer response method). The dispersion coefficient was obtained by adjusting the experimental profiles of tracer concentration with the predictions of the model. Experiment results of packed bubble column, shows a considerable reduction of the back mixing. The investigations have been carried out using RTD measurements and the back mixing is usually characterized by the axial dispersion coefficient obtained from the one-dimensional axial dispersion model. Also, a decrease in superficial gas velocity reduces the liquid back mixing. It is observed that the liquid circulation comprises an upward flow in the column core and a downward flow along the wall. It also seen that the transition from the bubbly flow to the pulsation flow regime occurred at 5-6 cm/s superficial gas velocity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.