Abstract

Two passive gas flow controllers are presented which provide compensation for variations in ambient temperature and supply pressure. One technique, which provides first-order error compensation, utilizes a choked orifice having its area linearily varied in proportion to a diaphragm deflection. Compensation is achieved by applying upstream pressure to one side of the diaphragm, and by applying a trapped gas pressure proportional to absolute temperature on the other side of the diaphragm. General design relationships are presented, and a prototype unit constructed to control a minute flow rate of high-pressure oxygen is described. A second flow control technique is presented which provides the required nonlinear temperature compensation for flow supplied through a constant-area choked orifice. This is achieved by utilizing a compliant volume of trapped gas to generate a pressure proportional to the square root of absolute temperature. This pressure is used to control the pressure upstream of the choked orifice, thus providing constant flow.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.