Abstract
AbstractWith the application of new technologies for coal mine gas control, it has been increasingly urgent to apply the fixed‐point closed sampling (FPCS) technology for accurate measurement of coal seam gas content. In this study, gas desorption during FPCS was analyzed. In addition, gas desorption experiments and COMSOL simulations were conducted on coal particles. Furthermore, the gas desorption law during FPCS was compared with that under atmospheric pressure. The results show that Sun's formula can effectively characterize the gas desorption law during FPCS, and the i value remains unchanged when the gas desorption curve is fitted with Sun's formula. On this basis, a specific method for calculating gas loss during FPCS by using Sun's formula was proposed. The research findings are expected to provide a theoretical basis for accurate measurement of coal seam gas content by means of FPCS.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.