Abstract
Reports results of an experimental investigation of the influence of gas desorption from electrodes on electrical breakdown in high vacuum (P=10-9 Torr). The gas composition was studied by a quadrupole mass-filter. Thermo-desorption of hydrogen from the anode was the dominant effect. A close correlation between gas evolution from the anode and changes in the slopes of Fowler-Nordheim plots for prebreakdown currents was established. Pressure bursts due to gas released from the anode at breakdown were observed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.