Abstract

The need to shape reactor cores in terms of coolant flow distributions arises due to the requirements for temperature fields in the core elements (Safety guide No. NS-G-1.12. 2005, IAEA nuclear energy series No. NP-T-2.9. 2014, Specific safety requirements No. SSR-2/1 (Rev.1) 2014). However, any reactor core shaping inevitably leads to an increase in the core pressure drop and power consumption to ensure the primary coolant circulation. This naturally makes it necessary to select a shaping principle (condition) and install heat exchange intensifiers to meet the safety requirements at the lowest power consumption for the coolant pumping. The result of shaping a nuclear reactor core with identical cooling channels can be predicted at a quality level without detailed calculations. Therefore, it is not normally difficult to select a shaping principle in this case, and detailed calculations are required only where local heat exchange intensifiers are installed. The situation is different if a core has cooling channels of different geometries. In this case, it will be unavoidable to make a detailed calculation of the effects of shaping and heat transfer intensifiers on changes in temperature fields. The aim of this paper is to determine changes in the maximum wall temperatures in cooling channels of high-temperature gas-cooled reactors using the combined effects of shaped coolant mass flows and heat exchange intensifiers installed into the channels. Various shaping conditions have been considered. The authors present the calculated dependences and the procedure for determining the thermal coolant parameters and maximum temperatures of heat exchange surface walls in a system of parallel cooling channels. Variant calculations of the GT-MHR core (NRC project No. 716 2002, Vasyaev et al. 2001, Neylan et al. 1994) with cooling channels of different diameters were carried out. Distributions of coolant flows and temperatures in cooling channels under various shaping conditions were determined using local resistances and heat exchange intensifiers. Preferred options were identified that provide the lowest maximum wall temperature of the most heat-stressed channel at the lowest core pressure drop. The calculation procedure was verified by direct comparison of the results calculated by the proposed algorithm with the CFD simulation results (ANSYS Fluent User’s Guide 2016, ANSYS Fluent. Customization Manual 2016, ANSYS Fluent. Theory Guide 2016, Shaw1992, Anderson et al. 2009, Petrila and Trif 2005, Mohammadi and Pironneau 1994).

Highlights

  • One of the major problems in implementing gas-cooled nuclear reactors is the high core thermal intensity due to the need to achieve a high coolant gas temperature, which, respectively, results in high cooling channel wall temperatures

  • At given total coolant flow and average core outlet temperature, the maximum wall temperature in the most heat-stressed channel group can be decreased if the coolant flow through the channels of this group is increased by shaping the mass flows

  • The paper focuses on the effect of changes in the maximum wall temperatures from the core coolant mass flow shaping using heat exchange intensifiers

Read more

Summary

Research Article

Academic editor: Boris Balakin ♦ Received 2 December 2018 ♦ Accepted 5 February 2019 ♦ Published 11 April 2019.

Introduction
Specific features of calculated dependences
Calculation results
Dependence f
Shaping condition
Comparison of
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.