Abstract
In the present study, the influence of gas compositional and pressure conditions on thermographic phosphor thermometry was investigated. A heatable pressurized and optical accessible calibration chamber was built to measure the phosphorescence decay time at different temperatures as well as at different partial and absolute pressures. At room temperature, the absolute pressure could be increased to 30 bar. To vary the gas composition, nitrogen, oxygen, carbon dioxide, methane, helium as well as water vapour were used. Three different phosphors were investigated: Mg4FGeO6:Mn, La2O2S:Eu and Y2O3:Eu. Phosphorescence was excited by the third and the fourth harmonics of a pulsed Nd:YAG-laser (355 nm and 266 nm, respectively) and recorded temporally resolved by a photomultiplier. Mg4FGeO6:Mn as well as La2O2S:Eu were not influenced significantly by varying partial and absolute pressures. In contrast, Y2O3:Eu showed a strong sensitivity on the oxygen concentration of the surrounding gas phase as well as irreversible changes in the phosphorescence decay time after increasing the absolute pressure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.