Abstract

A new method was developed for the identification and quantitative determination of normal alkanes in jet fuels and kerosene fractions on the basis of simulated distillation. Normal alkanes were identified on the chromatogram by their retention times, and their concentrations were calculated by absolute calibration, the results of which correspond to the results obtained by standard addition and internal standard methods. The developed method is simple and productive and can be carried out using standard analytical equipment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.